METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF ELEMENTAL IMPURITIES IN MEDROXYPROGESTERONE TABLETS 10mg BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
DOI:
https://doi.org/10.47750/pnr.2022.13.S06.154Keywords:
Medroxyprogesterone tablets 10mg, ICPMS, Method development, Method Validation, of Cadmium, Lead, Arsenic, Mercury, and Lithium.Abstract
The analytical method development and validation of Medroxyprogesterone tablets 10mg summarizes the outcome of the results for content of Cadmium, Lead, Arsenic, Mercury, and Lithium in by ICP-MS1. The test sample was prepared with microwave assisted acid digestion and introduced into optimized instrumental parameters for use of a quadruple based Agilent 7700 inductively coupled plasma mass spectrometry instrument. This method development and validation by ICP-MS to prove that it is Specific, Precise, Accurate, Linear, Robust, Reproducible and Capable of producing reliable results.